OCR: - Write - 321 BATTE.WRI File Edit Find ! Character Paragraph Document Help 3.2.1 BATTERY SERVICE ( 1 of 1 ) It is very important to start off this repair by following some exact procedures. Many batteries are replaced that are still good. [*] CAUTION - Always take care not to short positive to ground. 1. Check the fluid in ALL the cells of the battery. 2. Make sure the top of the battery is clean. 3. Check and clean the battery cables at both ends. Leave the negative cable off the battery. 4. Check the specific gravity with the hydrometer. If the specific gravity is not up to specs, then you should charge the battery at 3 to 6 amp for 4 to 6 hours or overnight. Recheck with hydrometer. If the battery won't take a proper charge, replace it. Always disconnect the negative cable first, then r ...